h igh r eliability r adiation t olerant cots xo | s pace s olutions date: 2 0 jul 2018 issue: s hortform, 51001204.110, issue a1 specifications subject to change without notice page 1 of 4 www. rakon. com requests can be emailed to : hirel@ rakon.com rk 1 0 5 5032 this radiation tolerant 5 x 3.2 mm hermetically sealed smd xo is specifically designed for missions where resistance to demanding environment , short lead - time and radiation tolerance are require d . i t combines a very low rms phase jitter, tight f requency stability and i s available with different types of fm screening options. 1. envir onmental conditions parameter condition / remarks min. typ. max. unit operating temperature option i: - 40 c to 85c o ption m : - 55c to 125c - 40 - 55 25 25 85 125 c switch - on temperature ts 0 - 55 125 c non - operating temperature tno p - 55 125 c m echa nical shock mil - std - 883, method 2002 (1500 g, 0.5 ms) humidity after 48 hours at 85c 2, 85% relative humidity non - condensing temperature cycling mil - std - 883, method 1010.8 ( - 55c, +125c, 1000 cycles) vibration mil - std - 883, method 2007 (20 g, 3 diffe rent axis, 4 times ) gross and fine leak mil - std - 883, method 1014 rohs compliant yes radiation : products have been tested up to the following levels without any events tid (ldr as per escc22900) sel (mev/mg/cm 2 ) set (mev/mg/cm 2 ) sefi (mev/mg/cm 2 ) cm os 100 krad 32.4 20 62.5 lvds 72 krad 32.4 10 62.5 lvpecl 72 krad 62.5 10 62.5 2. frequency characteristics parameter condition / remarks min. typ. max. unit a f d 1 option option i: - 40 c to 85c o ption m : - 55c to 125c 50 75 ppm initial frequency accuracy (fvt 2 option) 15 ppm frequency stability over temperature (fvt) option i: - 40c to 85c option m: - 55c to 125 c 30 50 ppm supply voltage stability (fvt) over operating temperature 3 ppm load sensitivity (fvt) over operating tempera ture 5 ppm ageing (fvt) over 10 years 15 ppm start - up time 10 ms 1 a f d: absolute frequency drift . it in cludes initial accuracy + temperature range + supply variation + load variation + ageing over 10 years. 2 fvt: frequency vs. temperature . features applications 5.0 x 3.2 mm ? free from export restrictions ? tid limit of 72/100 krad and latch - up free till 32.4/62 mev ? hermetically sealed package ? frequency range: 8 - 1500 mhz ? low consumption: 30 ma ? supply voltage: 2.5 or 3.3 v ? afd 1 50 ppm over - 40c to +85c ? different screening options ? missions where tid limit of 72/100 krad and latch - up free till 32.4/62 mev are required ? rugged environment
h igh r eliability r adiation t olerant cots xo | s pace s olutions date: 2 0 jul 2018 issue: s hortform, 51001204.110, issue a1 specifications subject to change without notice page 2 of 4 www. rakon. com requests can be emailed to : hirel@ rakon.com 3. electrical interface parameter condition / remarks min. typ. max. unit power supply (v dd ) option 2: 2.5 v option 3: 3.3 v 2.375 2.97 2.5 3.3 2.625 3.63 v stead state inpu t current power cmos output: lvds output lvpecl output 20 23 54 ma 4. output characteristics C cmos 3 parameter condition / remarks min. typ. max. unit nominal frequency cmos output 8 2 00 mhz output voltage ( v ol ) 15pf load 10% v dd v output vol tage ( v oh ) 15pf load 90% v dd v duty cycle @50% v dd 48 52 % rise time / fall time 90% to 1 0% vcc 3 ns rms phase jitter integrated 12 khz to 20 mhz 0.9 2.5 ps 5. output characteristics C lvpecl parameter condition / remarks min. typ. max. unit nom inal frequency lvpecl output 8 1500 mhz output voltage ( v ol ) 50 nominal load v dd C 1 .6v v output voltage ( v o h ) 50 nominal load v dd C 1.03v v duty cycle @ v dd C 1.03v (45 to 55% over 600 mhz) 48 52 % rise time / fall time 80% to 2 0% vcc 0.6 ns rms phase jitter integrated 12 khz to 20 mhz 0.9 2.5 ps 6. o utput characteristics C lvds parameter condition / remarks min. typ. max. unit nominal frequency lvds output 8 1500 mhz output voltage voltage swing ( v od ) 350 mv duty cycle measured @ 1. 25 v (45 to 55% over 150 mhz) 48 52 % rise time / fall time rl = 100 ? / cl = 10 pf 0.6 ns rms phase jitter integrated 12 khz to 20 mhz 0.9 2.5 ps 3 the cmos output is ttl compatible with the 3.3 v supply voltage .
h igh r eliability r adiation t olerant cots xo | s pace s olutions date: 2 0 jul 2018 issue: s hortform, 51001204.110, issue a1 specifications subject to change without notice page 3 of 4 www. rakon. com requests can be emailed to : hirel@ rakon.com 7. screening options screening operation requirements and condition options em fm0 fm1 fm2 stabilization bake (prior to seal) mil - std - 883 method 1008, conduction c C 24h@1 50c 24h@150c 24h@150c thermal shocks mil - std - 883, method 1011, condition a C ? ? ? temperature cycling mil - std - 883, method 1010, condition b C ? ? ? constant acceleration mil - std - 883, method 1010, condition a acceleration: 5000g, curing 60s in direct ion y1 C ? ? ? pind test mil - std - 883, method 2020, condition b ? ? ? ? seal test fine leak: mil - std - 883, method 1014, condition a2 ? ? ? ? gross leak: cei 68 - 2 - 17 test qc, method 1 ? ? ? ? pre burn - in measurement following the guidelines of mil - prf - 55 310, 4.8.5 , 4.8.6, 4.8.11, and 4.8.20 ? 4 ? 5 ? 5 ? burn - in temperature: +125c pressure: pa tm supply voltage: vcc n om load: load n om C C 160h min. 160h min. post burn - in measurement following the guidelines of mil - prf - 55310 C C ? ? pda C C 20% 10% e xternal visual inspection mil - std - 8 8 3 , method 2009 C C ? ? 8. ordering part example 4 electrical verification. 5 mil - std - 105e general inspection level | aql level 1.0. ? 100 pc s batch: test on 13 pcs / 0 rejected. ? 500 pcs batch: test on 20 pcs / 0 reject accepted. ? 1000 pcs batch: test on 50 pcs / 1 reject accepted. product family rk105 5032 = radiation tolerant . 5 x 3.2 mm xo output waveform cmos = cmos . lvds = lvd s . pecl = lvpecl frequency stability type fvt = frequency stabi lity over temperature range afd = absolute frequency drift frequency (fout) 100m = 100 mhz r k 1 0 5 5 0 3 2 c m o s - i - 3 - a f d - f m 1 - 1 0 0 m temperature range i = industry ( - 40c to +85c). m = military ( - 55c to 125c) radiation tolerance/screening option em = C / no screening f m 0 = radiation tolerant f m 1 = radiation tolerant / mil - std - 105e f m 2 = radiation tolerant / 100% supply voltage 2 = 2.5 v. 3 = 3.3 v
h igh r eliability r adiation t olerant cots xo | s pace s olutions date: 2 0 jul 2018 issue: s hortform, 51001204.110, issue a1 specifications subject to change without notice page 4 of 4 www. rakon. com requests can be emailed to : hirel@ rakon.com 9. model outline , pin connections and recommended pad layout 10. marking parameter test condition / description top line [r #### ## ] r and part identifier mid dle line [######] part information bottom line [o yww] pin 1, year code* and week code** year code* : a = 2010, b = 2011, c = 2012, d = 2013, z = 2035 week code** : ww = 01 = week of first monday of the year 11. manufacturing information parameter tes t condition / description packaging description <300 pcs: cut - tape >300 pcs: tape and reel. standard packing quantity is 2000 units per reel pb - free r eflow profile pin connections 1, 2 nc (not connected, for internal use only) 3 gnd (ground) 4 fout (frequ ency o utput ) 5 complementary output (lvpecl/lvds) or nc 6 v dd ( supply voltage) note: outline unit is mm. note: ? the product has been tested to withstand the reflow profile shown on the left hand side. ? the reflow profile used to solder rakon products i s determined by the solder paste manufactures specification. it is recommended that the reflow profile use does not exceed the one on the left .
|